BAMR (Pty) Ltd Supplier Coating Thickness Ultrasonic Quality Control Instruments Coating Thickness Elcometer Generator Low Cost Cape Town South Africa Generators Ultrasonic Material Wall Thickness Moisture Fibrescope Fiberscope Endoscopes Laboratory Paint Test Testing Meters Gloss Instrumentation Rhopoint Climatic Condition Measuring Dew Point Humidity RH Temperature Air Surface Liquid Infrared Surface Preparation & Profiles Hardness Inspectors’ Accessories  Adhesion Porosity Spark Sponge Pin Hole Concrete Thickness Covermeters Rebar detection Metal Locators Live Cable Detectors to 5m  Distance Meters: Ultrasonic Laser Leica Disto Digital Wheel Inclinometers Angle Level Meter Oven Temperature Logger Abrasion Testers Viscometers Ford 4
International Standards : ISO, ASTM, BS, DIN, SABS
Home Page Products Page Support News Web Links Contact Details Index of Products

Elcometer 456
Dry Film Coating Thickness Gauge
Miniature Probe Options


Click here to view a more Comprehensive Guide to choosing the correct digital dry film coating thickness gauge (DFTG) / paint thickness gauge.

Elcometer 456 Dry Film Thickness Gauge - MIniature Probes

The NEW range of ferrous and non-ferrous MINIATURE probes from Elcometer are ideal for taking measurements in hard to reach places or on small surface areas, which are not easily accessible using the normal Standard, Right Angle and Telescopic probes, simply because they are too large.

Ferrous and non-ferrous miniature probes are available with a measuring range of 0 - 500µm (0-20mils/thou) and two probe lengths options, 45mm or 150mm. The range consists of Straight, 45 Degree and 90 Degree angle probes making them ideal for accessing awkward areas such as:

  • Inner diameters

  • Thin diameter tubing

  • Narrow edges

  • Small curves

  • Applications at the bottom of small, deep bores.

Choosing the Correct Probe Type

Ferrous Probes use the Electromagnetic Induction Principle to measure non-magnetic coatings on a magnetic metal base. This includes paint, electroplating, galvanising, hard chrome, sprayed metal, powder coating, plastic, epoxy, rubber, ceramic, etc. on substrates such as steel, cast iron and ferritic and duplex stainless steel.

The Eddy Current Principle is used for all Non Ferrous Probes and can measure non-conductive coatings on non-ferrous metals including paint, anodising, vitreous enamel, plastic, epoxy, varnish power coating, glass fibre, rubber etc. on aluminum, copper, brass, austentitic (non-magnetic) stainless steel and other similar materials.

Miniature Probe Specifications

Measuring Range

0 - 500µm

Accuracy 2

±1-3% or ±2.5µm

Operating Temperature

Ferrous : Up to 150°C 1 ; Non Ferrous & FNF : Up to 80°C

Storage Temperature

-10 to 60°C

Resolution

Below 100µm: 0.1µm, 100 - 500µm: 1µm

Minimum Substrate Thickness

Ferrous : 0.3 mm; Non Ferrous : 0.1 mm

1 45mm Ferrous Straight Probe with sleeve fitted : Up to 80 °C
2 Accuracy ±1% when calibrated close to the required thickness, ±3% across the range
The accuracy quoted has been defined using a 100 micron foil, with the miniature probe held in a Probe Placement Jig.

Probe Type

Part Number

Overall Length (Headroom)*

Minimum Convex Diameter

Minimum Concave Radius

Minimum Sample Diameter

Minimum Access Requirements

Height

Width

FERROUS MINIATURE PROBES

Straight Miniature Probe, 45mm

T456FM3---A

1.5mm

6.5mm

3mm

6mm

150mm *

Straight Miniature Probe, 150mm

T456FM3---C

1.5mm

6.5mm

3mm

6mm

260mm *

45 Degree Miniature Probe, 45mm

T456FM3R45A

1.5mm

6.5mm

3mm

18mm

7mm

145mm

45 Degree Miniature Probe, 150mm

T456FM3R45C

1.5mm

6.5mm

3mm

18mm

7mm

250mm

90 Degree Miniature Probe, 45mm

T456FM3R90A

1.5mm

6.5mm

3mm

16mm

7mm

140mm

90 Degree Miniature Probe, 150mm

T456FM3R90C

1.5mm

6.5mm

3mm

16mm

7mm

245mm

NON-FERROUS MINIATURE PROBES

Straight Miniature Probe, 45mm

T456NM3---A

3mm

25mm

4mm

6mm

150mm *

Straight Miniature Probe, 150mm

T456NM3---C

3mm

25mm

4mm

6mm

260mm *

45 Degree Miniature Probe, 45mm

T456NM3R45A

3mm

25mm

4mm

18mm

7mm

145mm

45 Degree Miniature Probe, 150mm

T456NM3R45C

3mm

25mm

4mm

18mm

7mm

250mm

90 Degree Miniature Probe, 45mm

T456NM3R90A

3mm

25mm

4mm

16mm

7mm

140mm

90 Degree Miniature Probe, 150mm

T456NM3R90C

3mm

25mm

4mm

16mm

7mm

245mm

* The above capabilities have been determined using a calibration foil of 100 microns and the probe held in a probe placement jig.

Elcometer 456 Dry Film Coating Thickness Gauge - pdf Brochure

Elcometer 456 Dry Film Coating Thickness Gauge - Technical Specifications

Elcometer 456 Coating Thickness Gauge  Dry Film Thickness Gauge DFTG Paint Standards

Elcometer 456 Dry Film Coating Thickness Gauge - Probe Options

Elcometer 456 Dry Film Coating Thickness Gauge Probe Options - pdf Brochure

Elcometer 456 Dry Film Coating Thickness Gauge PINIP Probe Options - pdf Brochure

Elcometer 456 Dry Film Coating Thickness Gauge - pdf Brochure

Elcometer 456 Dry Film Coating Thickness Gauge - Quick Guide pdf Brochure

Elcometer 456 Dry Film Coating Thickness Gauge - Operating Manuals / Instructions