The Elcometer 456 Probes are intelligent. This means:
All Ferrous (F) Models will accept any Ferrous Probe
-
All Non Ferrous (N) Models will accept any Non Ferrous Probe
-
All Dual Ferrous & Non Ferrous (FNF) Models will accept
-
Any Ferrous (F)
-
Any Non Ferrous (N) and
-
Any Dual Ferrous/Non Ferrous (FNF) Probes
The Elcometer 456 Probes allow totally versatile application of the Elcometer 456 Coating Thickness Gauges to different coating thickness measurement tasks. Various probe ranges, resolution, size and access capabilities can be freely interchanged as required on both ferrous (F) and non-ferrous (N) metal substrates.
Combining over 45 years of probe design and build experience, with the latest materials and technology, the new Elcometer probes are even more accurate, repeatable and reliable than ever before. Available in a number of designs and scale ranges to meet your specific application, all probes are supplied with an Elcometer test certificate and a set of calibration foils†
Straight
-
Measures coatings on both flat and curved surfaces
Right Angle
-
For taking readings where access is restricted
Mini
-
Ideal for edges, narrow pipes and small surfaces areas
PINIP
-
Plug-in probes convert a separate to an integral gauge
Telescopic
-
Extending right angled probes for out of reach areas
Waterproof
-
Sealed for use under water at depth, even in diving gloves
High Temp
-
For use on hot coated materials up to 250°C
Anodiser
-
Chemical resistant washable probes ideal for the anodising environment
Armoured
-
Probes with metal reinforced heavy duty cables
Soft Coating
-
Large surface area probes for soft materials (HVCA approved)
Measurement Options
Ferrous (F) operation using electromagnetic induction probes for all non-magnetic coatings on a ferrous (magnetic) substrate, e.g. paint, plastic, enamel, powder, rubber, ceramic, galvanising, zinc, sprayed metal (aluminium or zinc), etc. on steel, cast iron, ferritic and duplex stainless steel, substrates etc.
Non-Ferrous (N) operation using eddy current probes for non-conductive coatings on non-ferrous metal substrates, e.g. anodising, paint, powder, lacquer, plastic, etc. on aluminium, brass, zinc, stainless steel, copper, titanium substrates etc.
Dual (FNF) operation combines the Ferrous and Non-Ferrous operation in a single probe. The gauge has user selection for auto or manual substrate determination.
Technical Specifications
|
Ferrous |
Non Ferrous & FNF |
PINIP |
Max Operating Temperature |
Up to 150°C |
Up to 80°C |
Up to 50°C |
Storage Temperature |
-10 - 60°C |
Minimum Substrate Thickness |
0.3 mm |
0.1 mm |
|
†Foil sets are appropriate to the separate probe's scale range
Scale 1
Range: 0-1500µm
Accuracy : ±1-3% or ±2.5µm
Resolution: 0.1µm: 0-100µm; 1µm: 100-1500µm
Probe Design |
|
Ferrous |
Non-Ferrous |
Dual Probe |
Minimum |
Minimum Sample |
|
|
F |
N |
FNF |
Headroom |
† Diameter |
|
|
|
|
|
|
|

|
Straight |
T456CF1S |
T456CN1S |
T456CFNF1S |
F, N |
85mm |
F, N, FNF (F) |
4mm |
FNF |
88mm |
FNF (N) |
6mm |

|
Right Angle |
T456CF1R |
T456CN1R |
T456CFNF1R |
F, N |
28mm |
F, N, FNF (F) |
4mm |
FNF |
38mm |
FNF (N) |
6mm |

|
Mini M5-90° 45mm
|
T456CFM5R90A |
- |
- |
F |
16mm |
F |
7mm |

|
Anodiser |
T456CN1AS |
- |
- |
N |
100mm |
N |
4mm |

|
PINIP |
T456CF1P |
T456CN1P |
T456CFNF1P |
F |
170mm |
F, N, FNF (F) |
4mm |
N, FNF |
180mm |
FNF (N) |
6mm |
Scale 2
Range: 0-5mm (0-200mils) *
Accuracy : ±1-3% or ±20µm
Resolution: 0.1µm: 0-1mm; 10µm: 1-5mm
For higher resolution & accuracy on thin coatings Scale 2 ferrous probes can be switched to the Scale 1 mode measurement performance
Probe Design |
|
Ferrous |
Non-Ferrous |
Dual Probe |
Minimum |
Minimum Sample |
|
|
F |
N |
FNF |
Headroom |
† Diameter |
|
|
|
|
|
|
|
|
|

|
Straight |
T456CF2S |
T456CN2S |
- |
F |
89mm |
F |
8mm |
N |
88mm |
N |
14mm |

|
Right Angle |
T456CF2R |
- |
- |
F |
32mm |
F |
8mm |

|
Armoured |
T456CF2ARM |
- |
- |
F |
138mm |
F |
8mm |

|
Telescopic |
T456CF2T |
- |
- |
F |
36mm |
F |
8mm |

|
Soft Coating |
T456CF2B |
- |
- |
F |
89mm |
F |
8mm |

|
Waterproof |
T456CF2SW |
- |
- |
F |
89mm |
F |
8mm |

|
Waterproof |
T456CF2SW-5 |
- |
- |
F |
89mm |
F |
8mm |

|
Waterproof |
T456CF2SW-15 |
- |
- |
F |
89mm |
F |
8mm |

|
PINIP |
T456CF2P |
T456CN2P |
- |
F |
174mm |
F |
8mm |
N |
185mm |
N |
14mm |

|
Hi-Temp |
T456CF2PHT |
- |
- |
F |
174mm |
F |
8mm |
Scale 3
Range: 0-13mm
Accuracy : ±1-3% or ±50µm
Resolution: 0.1µm: 0-2mm; 10µm: 2-13mm
Probe Design |
|
Ferrous |
Non-Ferrous |
Dual Probe |
Minimum |
Minimum Sample |
|
|
F |
N |
FNF |
Headroom |
† Diameter |

|
Straight |
T456CF3S |
- |
- |
F |
102mm |
F |
14mm |

|
PINIP |
T456CF3P |
- |
- |
F |
184mm |
F |
14mm |
Scale 6
Range:
F: 0-25mm
N: 0-30mm
Accuracy : ±1-3% or ±100µm
Resolution: 10µm: 0-2mm; 100µm: 2-30mm
Probe Design |
|
Ferrous |
Non-Ferrous |
Dual Probe |
Minimum |
Minimum Sample |
|
|
F |
N |
FNF |
Headroom |
† Diameter |

|
Straight |
T456CF6S |
T456CN6S |
- |
F |
150mm |
F |
51x51mm2 |
N |
160mm |
N |
58mm |

|
Armoured |
T456CF6ARM |
T456CN6ARM |
- |
F |
190mm |
F |
51x51mm2 |
N |
200mm |
N |
58mm |
Scale 0 . 5
Range: 0-500µm
Accuracy : ±1-3% or ±2.5µm
Resolution: 0.1µm: 0-100µm; 1µm: 100-500µm
Probe Design |
|
Ferrous |
Non-Ferrous |
Dual Probe |
Minimum |
Minimum Sample |
|
|
F |
N |
FNF |
Headroom |
† Diameter |

|
Mini M3 |
T456CFM3---A |
T456CNM3---A |
- |
F |
6mm |
F |
3mm |
N |
6mm |
N |
4mm |

|
Mini-M3-90 |
T456CFM3R90A |
T456CNM3R90A |
- |
F |
16mm |
F |
3mm |
N |
16mm |
N |
4mm |

|
Mini-M3-45 |
T456CFM3R45A |
- |
- |
F |
18mm |
F |
3mm |
N |
4mm |

|
Mini-M3-90 |
T456CFM3R90C |
T456CNM3R90C |
- |
F |
16mm |
F |
3mm |
N |
16mm |
N |