Standards E
|
Equivalent to ISO Standard 8502-6 Extraction of soluble contaminants for analysis -- The Bresle method; meets the requirements of ISO Standard 8502-9 Field method For the conductometric determination of water-soluble salts. |
Measurement Area |
1250 mm (circular) fixed footprint |
Attachment Method |
Magnetic with silicone seal (no effect on surface quality; proven to seal over deep pits) |
Water Injection Method |
Automated, with simple press of fixed volume dispenser |
Dose |
3 ± 0.05 ml |
Measurement Process Steps |
5 |
Total Process Time |
60 seconds |
Probe Range |
0-300 µS/cm |
Resolution |
1 µS/cm |
Measurement Accuracy |
± 3 µS/cm |
Surface Temperature Range |
5 - 50 °C |
Temperature probe accuracy |
± 0,3 °C |
Minimum radius of curvature |
550mm |
Memory |
Holds up to 1000 measurements (10 batches of up to 100 measurements each)
|
Connectivity |
via USB with PC or laptop |
Power Supply |
Lithium-ion rechargeable battery |
IP Rating |
IP54 |
Dimensions (Instrument only) |
21 x 10 x 8 cm |
Weight (Instrument only) |
780 g |