Product Description

Elcometer 1615 Variable Impact Tester

The Elcometer 1615 Variable Impact Tester is a simple to use gauge is ideal for evaluating the resistance of a coating to impact (elongation, cracking or peeling).There are two test methods: either a weight with a hemispherical punch attached falls on a coated metal sheet or a weight falls on to a hemispherical punch which is resting on the coated metal sheet.

The Elcometer 1615 Impact Tester comes as one universal assembly with the option of six different kits in order to test a sample in accordance with a range of National and International standards.

The test specimen is fixed into position by the quick release clamp. The weight is lifted to the predetermined height and can be set by the adjustable collar device. The weight is then released and the resulting deformation is observed.

  • The base unit is common to all tests. Simply select the appropriate kit to meet your requirements.
  • Heavy-duty passivated base plate and anodised arm for long life
  • Graduated tube with engraved markings
  • Quick, safe weight release mechanism
  • Integrated bubble level to ensure the tester is perpendicular for accurate results
  • Stop collar with 10 settings between 2mm and 15mm to change the depth of impact when working in accordance with ISO Standards, supplied with Kits A, D and F
  • Easy fix sample clamp – the test sample can be secured or released by a simple twist of the clamp handle supplied with Kits A, D and F
  • Magnifier x 10

The tube has clearly engraved, graduated markings in both kg-c and lb-inch to ensure accuracy and a quick, safe weight release mechanism which holds the weight safely and allows a smooth release.

Tube height: 1000mm

The stop collar, supplied with Kits A, D and F or as an optional accessory, allows the penetration depth to be limited. By rotating the stop collar, the user can select the depth required between 2-15mm.

Values: 2,3,4,5,6,7,8,9,10 and 15mm

Each Impact Tester is supplied with an integrated bubble level ensuring accurate setup prior to any test.

The Elcometer 1615 Variable Impact Testers are designed to meet a wide range of National and International Standards. Simply select the appropriate kit and attach the punch, die and accessories to the base unit. Interchangeable die – enables the user to match the die to the size of the relevant punch to conform to the required Standard or method.

The optional easy to fix sample clamp enables the user to quickly and safely secure the sample.

The Elcometer 1615 Variable Impact Tester can be used in accordance with:

  • ISO 6272:1993
  • ISO 6272-1
  • ISO 6272-2
  • ASTM D 2794
  • ASTM D 5420
  • AS/NZS 1580.406.1
  • BS 6496:1984
  • BS 3900-E13
  • ECCA T5
  • EN 12206-1:2004
  • EN 13523-5
  • JIS K 5600-5-3:1999
  • NFT30-017:1989

Standards not in bold have been superseded but are still recognised in some industries.

 

Specifications

Elcometer 1615 Variable Impact Testers – Specifications

Part Number Description Certificate
K0001615KITA Elcometer 1615 Kit A to meet ISO 6272:1993 Standard ο
K0001615KITB Elcometer 1615 Kit B to meet ISO 6272 Part 2:2002 Standard ο
K0001615KITC Elcometer 1615 Kit C to meet ASTM D2794 Method 2, BS6486:1984, EN 12206-1 Standards ο
K0001615KITD Elcometer 1615 Kit D to meet ISO 6272 Part 1:2002, BS EN ISO 6272-1:2004 Standards ο
K0001615KITE Elcometer 1615 Kit E to meet NF T30-017:1989 Standard ο
K0001615KITF Elcometer 1615 Kit F to meet ISO 6272:1993, ISO 6272-2:2002 Standards ο
K0001615KITG Elcometer 1615 Kit G to meet BS EN ISO 6272-2:2011 Standard ο
Packing List Kit A: Sample clamp, 27mm (1.06″) die, 1kg (2.2lb) falling weight with a 20mm (0.79″) punch, stop collar, 2 x hexagonal wrench and operating instructions
Kit B: Indenter with 15.9mm (0.6″) punch, die 16.3mm (0.64″), falling 1kg (2.2lb) weight, hexagonal wrench and operating instructions
Kit C: Indenter with 15.9mm (0.6″) punch, 2lb (0.91kg) falling weight and operating instructions
Kit D: 1kg (2.2lb) falling weight with 20mm (0.79″) punch, 27mm (1.06″) die, stop collar, hexagonal wrench and operating instructions
Kit E: 400g (0.88lb) falling weight with a 23mm (0.9″) punch, 22mm (0.87″) die, sample clamp, hexagonal wrench and operating instructions
Kit F: Sample clamp, stop collar, 27mm (1.06″) die, 1kg falling indenter with a 20mm (0.79″) punch, indenter with 15.9mm (0.6″) punch, 12.7mm (0.5″) punch, 16.3mm (0.6″) die, falling 1kg weight, 2 x hexagonal wrench and operating instructions
Kit G: Falling 1kg (2.2lb) weight with a 15.9mm (0.62″) static indenter with handle and punch; 12.7mm (0.5″) static indenter with handle and punch; 16.3mm (0.64″) die with fixing screw; guide bracket with two fixing screws; 3mm (0.12″) hexagonal wrench; 4mm (0.16″) hexagonal wrench


Elcometer Impact Tester Kit AKit A
 – Part Number: KT001615KITA

Standards: ISO 6272:1993, EN 13523, JIS K 5600-5-3. DIN EN ISO 6272-1

Packing List:

  • Falling 1kg weight with a 20mm punch
  • Stop collar
  • 27mm die with fixing screw
  • Sample clamp with two fixing screws
  • 3mm and 4mm hexagonal wrench

 

Elcometer Impact Tester Kit BKit B – Part Number: KT001615KITB

Standards: ASTM D 2794, BS EN ISO 6272-2, ISO 6272-2: 2002, Qualicoat

Packing List:

  • Static indenter with 15.9mm punch
  • Falling 1kg weight
  • 12.7mm punch
  • 16.3mm die with fixing screw
  • 3mm hexagonal wrench

 

Elcometer Impact Tester Kit CKit C – Part Number: KT001615KITC

Standards: ASTM D 2794, ASTM D 5420, BS6496:1984, EN 12206-1

Packing List:

  • Static indenter with 15.9mm punch
  • Falling 908g weight
  • 16.3mm die with fixing screw
  • 3mm hexagonal wrench

 

 Elcometer Impact Tester Kit DKit D – Part Number: KT001615KITD

Standards: ISO 6272-1, BS EN ISO 6272-1, NF EN ISO 6272-1

Packing List:

  • Falling 1kg weight with 20mm punch and stop key
  • 27mm die with fixing screw
  • Stop collar
  • Sample clamp with fixing screws
  • 3mm and 4mm hexagonal wrench

 

Elcometer Impact Tester Kit EKit E – Part Number: KT001615KITE

Standards: NF T30-017:1989

Packing List:

  • Falling 400g weight with 23mm punch
  • 22mm die with fixing screw
  • 3mm hexagonal wrench

 

 

Elcometer Impact Tester Kit FKit F – Part Number: KT001615KITF

Standards:  ASTM D 2794, BS EN ISO 6272, DIS EN ISO 6272-1, EN 13523-5, ISO 6272, Qualicoat 2006, SN EN ISO 6272-1

Packing List:

  • Falling 1kg (2.2lb) weight with a 20mm (0.7″) punch
  • Stop collar
  • 27mm (1.06″) die with fixing screw
  • Sample clamp with two fixing screws
  • 3mm (0.12″) and 4mm (0.15″) hexagonal wrench
  • Static indenter with 15.9mm (0.6″) punch
  • Falling 1kg (2.2lb) weight
  • 12.7mm (0.5″) punch
  • 16.3mm (0.64″) die with fixing screw

 

 Elcometer Impact Tester Kit GKit G Part Number: KT001615KITG

Standards: BS EN ISO 6272-2:2011

Packing List:

  • Falling 1kg weight with a 15.9mm static indenter with handle and punch
  • 12.7mm static indenter with handle and punch
  • 16.3mm die with fixing screw
  • Guide bracket with two fixing screws
  • 3mm hexagonal wrench
  • 4mm hexagonal wrench

Data Sheet

Standards

Elcometer 1615 Variable Impact Testers – Standards

The Elcometer 1615 Variable Impact Tester can be used in accordance with:

  • ISO 6272:1993
  • ISO 6272-1
  • ISO 6272-2
  • ASTM D 2794
  • ASTM D 5420
  • AS/NZS 1580.406.1
  • BS 6496:1984
  • BS 3900-E13
  • ECCA T5
  • EN 12206-1:2004
  • EN 13523-5
  • JIS K 5600-5-3:1999
  • NFT30-017:1989

Standards not in bold have been superseded but are still recognised in some industries.

Accessories

Elcometer 1615 Variable Impact Testers – Accessories

Punches are universal and can be used either fitted to a falling weight or as a punch resting on the sample.
Suitable for Kit
A B C D E F G
KT001615N201 Additional 1kg (2.2lb) Falling Weight, 24.6mm (0.97″) Diameter
KT001615N221 Additional 1kg (2.2lb) Falling Weight, 25.0mm (0.98 ) Diameter
KT001615N226 20mm (0.79”) Diameter Punch (Outside Diameter 25mm)
KT001615N215 12.7mm (0.5″) Diameter Punch
KT001615N205 15.9mm (0.6″) Diameter Punch
KT001615N206 20mm (0.79″) Diameter Punch
KT001615N207 23mm (0.9″) Diameter Punch
KT001615N216 Static Indenter with 12.7mm/0.5” Diameter Punch
KT001615N217 Static Indenter with 15.9mm/0.6” Diameter Punch
KT001615N208 Stop Ring Collar
KT001615N209 Sample Clamp Mechanism
KT001615N210 Weight Release Mechanism
KT001615N211 Replacement Graduated Tube
KT001615N212 16.3mm (0.64″) Die
KT001615N232 16.3mm (0.64”) Die (with 1.5mm Radius)
KT001615N213 22mm (0.67″) Die
KT001615N214 27mm (1.06″) Die

 

Instruction Manual

Elcometer 1615 Variable Impact Testers – Instruction Manual