The Elcometer 205, 206 and 206 DL Ultrasonic Thickness Gauges are a range of three robust, hand-held gauges for making reliable thickness measurements or scanning a length of material for defects or its thinnest point using scan mode. These models have been discontinued; please contact us for a recommendation of a suitable replacement. The gauges address a routine inspection problem: measuring remaining material thickness, and finding the worst point of corrosion or wear, from one side only, without cutting into the part.
Each gauge offers three calibration options, single point, two point and speed of sound selection, allowing accurate measurements across a wide range of materials. They are compatible with a wide range of measurement transducers and all include a backlight for measuring in darkened environments. The gauges are available with or without memory: the higher models add differential mode and alarm mode, with the Elcometer 206 DL providing data logging and ElcoMaster software for transferring and reporting readings. Scan mode captures the minimum recorded thickness as the probe is moved across the surface.
The gauges can be used in accordance with ASTM E797 and EN 15317, the recognised methods for ultrasonic thickness measurement. They are used in corrosion monitoring, maintenance and inspection across petrochemical, marine, structural steel and general industry. As these models are discontinued, BAMR, South Africa's authorised Elcometer distributor, can advise on a current replacement to suit your application.
Elcometer 205, 206 and 206 DL Ultrasonic Thickness Gauges - Discontinued
The Elcometer 205, 206 and 206 DL Ultrasonic Thickness Gauges gives you a range of 3 robust, hand held gauges allows you to make reliable measurements or scan a length of material for defects or the thinnest point using the scan mode. Each gauge comes with 3 calibration options: single point, 2 point and speed of sound selection - allowing accurate measurements on a wide range of materials. Compatible with a wide range of measurement transducers, these ultrasonic thickness gauges are available with or without memory and all come with a backlight for measuring in darkened environments.
BAMR no longer supplies this product.
Specifications
• = available / compatible with that option or model
| Part Number | C205-1 | C206-1 | C206DL-1 |
|---|---|---|---|
| Model | Elcometer 205 | Elcometer 206 | Elcometer 206DL |
| Scan Mode | • | • | • |
| Differential Mode | • | • | |
| Alarm Mode | • | • | |
| Data Output (Immediate) | • | • | |
| Data Logging | 1000 readings | ||
| ElcoMaster™ software | • | ||
| Maximum Measurement Range | 0.63 – 500mm ,dependent on transducer and material | ||
| Operating Temperature | -30°C to 50°C |
- Velocity Range
- 1250 – 10000m/s
- Accuracy
- ±0.1mm , dependent on material and conditions
- Resolution
- 0.01mm
- Units
- Millimeters and inches
- Keypad Type
- Sealed Membrane
- Display
- 114mm Digit Liquid Crystal Display with backlight
- Transducer
- Select from transducer options
- Battery Type
- AA 1.5V Alkaline or 1.2V NiCad cell
- Battery Life
- 200 hours Alkaline/120 hours NiCad
- Weight
- 295g
- Dimensions
- 63 x 120 x 31mm
- Certificate available
- Certificate of Calibration: issued for Fixed Calibration equipment and shows readings and traceability.
- Accredited Certificate: can be issued for Fixed Calibration Equipment and a full UKAS traceable certificate is issued from an independent Calibration Laboratory.
- Elcometer 206DL Model
- C206DL
- 3.8-50.8mm range, 1MHz brown, 12.7mm crystal
- T92015620
- 3.8-50.8mm range, right angle
- T92015621
- 3.8-50.8mm range, microdot
- T92015622
- 3.8-50.8mm range, potted
- T92015623
- 5-75mm range
- T92015626
- 5-75mm range, right angle
- T92015627
- 5-75mm range, microdot
- T92015628
- 5-75mm range, potted
- T92015629
- 10-100mm range
- T92015631
- 10-100mm range, right angle
- T92015632
- 10-100mm range, microdot
- T92015633
- 10-100mm range, potted
- T92015634
- 15-200mm range
- T92015635
- 15-200mm range, right angle
- T92015636
- 15-200mm range, microdot
- T92015637
- 15-200mm range, potted
- T92015638
- 2.5-20mm range
- T92015641
- 2.5-20mm range, right angle
- T92015642
- 1.2-12.7mm range, high temp
- T92015644
- 0.5-6.35mm range
- T92015645
- 0.5-6.35mm range, right angle
- T92015646
- 0.5-6.35mm range, microdot
- T92015647
- 0.5-6.35mm range, potted
- T92015648
- 5-75mm range, cast iron
- T92015655
- 5-75mm range, cast iron right angle
- T92015656
- 5-75mm range, cast iron microdot
- T92015657
- 3.8-50.8mm range, plastic
- T92015658
- 3.8-50.8mm range, glass fibre
- T92015659
- 5-75mm range, plastic
- T92015660
- 5-75mm range, glass fibre
- T92015661
- 10-100mm range, plastic
- T92015662
- 10-100mm range, glass fibre
- T92015663
- 15-200mm range, plastic
- T92015664
- 15-200mm range, glass fibre
- T92015665
- 2.5-20mm range, plastic
- T92015666
- 2.5-20mm range, glass fibre
- T92015667
- 2.5-20mm range, thin glass fibre
- T92015668
- 0.5-6.35mm range, thin glass fibre
- T92015669
- 5-75mm range, aluminium
- T92015670
- 10-100mm range, aluminium
- T92015671
- 15-200mm range, aluminium
- T92015672
- 2.5-20mm range, aluminium
- T92015673
- 0.5-6.35mm range, aluminium
- T92015674
- 3.8-50.8mm range, extra resolution
- T92015676
- 5-75mm range, extra resolution
- T92015677
- 10-100mm range, extra resolution
- T92015678
- 15-200mm range, Exxon specification
- T92015679
Specifications
Specifications
• = available / compatible with that option or model
| Part Number | C205-1 | C206-1 | C206DL-1 |
|---|---|---|---|
| Model | Elcometer 205 | Elcometer 206 | Elcometer 206DL |
| Scan Mode | • | • | • |
| Differential Mode | • | • | |
| Alarm Mode | • | • | |
| Data Output (Immediate) | • | • | |
| Data Logging | 1000 readings | ||
| ElcoMaster™ software | • | ||
| Maximum Measurement Range | 0.63 – 500mm ,dependent on transducer and material | ||
| Operating Temperature | -30°C to 50°C |
- Velocity Range
- 1250 – 10000m/s
- Accuracy
- ±0.1mm , dependent on material and conditions
- Resolution
- 0.01mm
- Units
- Millimeters and inches
- Keypad Type
- Sealed Membrane
- Display
- 114mm Digit Liquid Crystal Display with backlight
- Transducer
- Select from transducer options
- Battery Type
- AA 1.5V Alkaline or 1.2V NiCad cell
- Battery Life
- 200 hours Alkaline/120 hours NiCad
- Weight
- 295g
- Dimensions
- 63 x 120 x 31mm
- Certificate available
- Certificate of Calibration: issued for Fixed Calibration equipment and shows readings and traceability.
- Accredited Certificate: can be issued for Fixed Calibration Equipment and a full UKAS traceable certificate is issued from an independent Calibration Laboratory.
- Elcometer 206DL Model
- C206DL
- 3.8-50.8mm range, 1MHz brown, 12.7mm crystal
- T92015620
- 3.8-50.8mm range, right angle
- T92015621
- 3.8-50.8mm range, microdot
- T92015622
- 3.8-50.8mm range, potted
- T92015623
- 5-75mm range
- T92015626
- 5-75mm range, right angle
- T92015627
- 5-75mm range, microdot
- T92015628
- 5-75mm range, potted
- T92015629
- 10-100mm range
- T92015631
- 10-100mm range, right angle
- T92015632
- 10-100mm range, microdot
- T92015633
- 10-100mm range, potted
- T92015634
- 15-200mm range
- T92015635
- 15-200mm range, right angle
- T92015636
- 15-200mm range, microdot
- T92015637
- 15-200mm range, potted
- T92015638
- 2.5-20mm range
- T92015641
- 2.5-20mm range, right angle
- T92015642
- 1.2-12.7mm range, high temp
- T92015644
- 0.5-6.35mm range
- T92015645
- 0.5-6.35mm range, right angle
- T92015646
- 0.5-6.35mm range, microdot
- T92015647
- 0.5-6.35mm range, potted
- T92015648
- 5-75mm range, cast iron
- T92015655
- 5-75mm range, cast iron right angle
- T92015656
- 5-75mm range, cast iron microdot
- T92015657
- 3.8-50.8mm range, plastic
- T92015658
- 3.8-50.8mm range, glass fibre
- T92015659
- 5-75mm range, plastic
- T92015660
- 5-75mm range, glass fibre
- T92015661
- 10-100mm range, plastic
- T92015662
- 10-100mm range, glass fibre
- T92015663
- 15-200mm range, plastic
- T92015664
- 15-200mm range, glass fibre
- T92015665
- 2.5-20mm range, plastic
- T92015666
- 2.5-20mm range, glass fibre
- T92015667
- 2.5-20mm range, thin glass fibre
- T92015668
- 0.5-6.35mm range, thin glass fibre
- T92015669
- 5-75mm range, aluminium
- T92015670
- 10-100mm range, aluminium
- T92015671
- 15-200mm range, aluminium
- T92015672
- 2.5-20mm range, aluminium
- T92015673
- 0.5-6.35mm range, aluminium
- T92015674
- 3.8-50.8mm range, extra resolution
- T92015676
- 5-75mm range, extra resolution
- T92015677
- 10-100mm range, extra resolution
- T92015678
- 15-200mm range, Exxon specification
- T92015679
Standards
Standards
Accessories
Accessories
| T92015701 | Ultrasonic Couplant 120ml Bottle |
| T92015874 | High Temperature Ultrasonic Couplant 60ml Bottle |
| T9205243 | Test Wedge: 2 – 25mm in 6 steps |
| T9205270 | Test Wedge: 30 – 100mm in 8 steps |
| Measurement Range | Material |
| in steel (mm) | C a s t I r o n |
| 3.8-50.8 | ● |
| ● | |
| ● | |
| ● | |
| 1.5-101.6 | ● |
| ● | |
| ● | |
| ● | |
| ● | |
| ● | |
| 1.5-127.0 | ● |
| ● | |
| ● | |
| ● | |
| ● | |
| ● | |
| 1.5-50.8 | |
| 1.02-152.4 | |
| 1.27-507.7 | |
| 1.02-152.4 | |
| 0.635-152.4 | |
| 1.02-152.4 | |
| 1.52-254.0 |
Sound Velocities
Sound Velocities
| Material | m/s | Material | m/s | ||
|---|---|---|---|---|---|
| Metals | |||||
| A | Aluminium | 6 320 - 6 400 | M | Molybdenum | 6 250 - 6 300 |
| Aluminium (2024-T4) | 6 380 | Mercury | 1 450 | ||
| Asbestos Cement | 2 200 | N | Nickel | 5 480 - 6 040 | |
| B | Beryllium | 12 880 | P | Platinum | 3 690 |
| Boron Carbide | 10 920 | S | Silver | 3 600 - 3 700 | |
| Brass | 4 390 | Steel, Mild | 5 900 - 6 100 | ||
| C | Cast Iron | 3 500 - 5 600 | Steel, Casting (4340) | 5 850 | |
| Cast Iron (Modular Graphite) | 5 600 | Steel, 303 Stainless (Austenitic) | 5 660 - 6 120 | ||
| Cast Grey Middle | 4 600 | Stellite | 7 050 | ||
| Copper | 4 650 - 4 720 | T | Tin | 3 300 - 3 330 | |
| Cadmium | 2 770 - 2 800 | Titanium | 5 900 - 6 100 | ||
| Chromium | 6 200 | Tungsten Carbon | 6 650 | ||
| G | Gold | 3 200 - 3 250 | Tungsten | 5 180 - 5 400 | |
| I | Inconel | 5 820 | U | Uranium | 3380 |
| Iron | 5 890 - 5 930 | W | Wolfram | 5 460 | |
| L | Lead | 1 960 - 2 400 | Z | Zinc | 4 170 - 4 320 |
| M | Manganese | 4 660 - 4 700 | Zircaloy 2 | 4 700 | |
| Magnesium | 5 770 - 5 840 | Zirconium | 4 650 | ||
| Non-Metal | |||||
| A | Acrylic | 2 870 | N | Nylon | 2 600 - 2 690 |
| Acrylic Resin | 2 730 - 2 870 | O | Oil (SAE 30) | 1 740 | |
| Air | 330 | P | Paraffin Wax | 2 200 | |
| Aluminium Oxide | 8 700 | Perspex | 2 860 | ||
| C | Ceramic (Macor) | 5 631 | Phenolic | 1 400 | |
| Diamond | 17 500 | Plexi Glass | 2 690 | ||
| Diesel Oil | 1 250 | Polyamide | 2 380 | ||
| Epoxy Resin | 2 650 | Polyethylene | 1 900 - 2 400 | ||
| G | Glass (Flint) | 4 260 | Polyurethane | 1 780 - 1 900 | |
| Glass (Crown) | 5 260 - 6 120 | Polystyrene | 2 340 - 2 400 | ||
| Glass (Quartz) | 5 570 | Porcelain | 5 600 - 5 900 | ||
| Glass (Window) | 6 800 | PVC | 2 400 | ||
| Glycerine | 1 930 | Q | Quartz X Cut | 5 740 | |
| I | Ice | 3 980 | Quartz Fused | 5 980 | |
| H | Hi-Density Polyethelene | 2 220 - 2 300 | Rubber (Butyl) | 1 900 | |
| (Grey & White, Not Black) | R | Rubber (Soft) | 1 480 | ||
| M | Methylene-Oxide | 9 980 | Rubber (Vulc.) | 2 300 | |
| Monel | 5 360 - 5 400 | S | Silicone Rubber | 948 | |
| Motor Oil (SAE 30) | 1 750 | T | Teflon | 1 350 - 1 520 | |
| N | Neoprene | 1 600 | W | Water | 1470 |
- Note
- This Schedule is only a Guide
Ask about the Elcometer 205, 206 and 206 DL Ultrasonic Thickness Gauges - Discontinued and its alternatives.
Tell us about your application and we will send a quote with lead time and accessories.
Not sure this is the right model for your job? for a quick recommendation.
Check availability
Ask about availability
Tell us about your application and we will confirm remaining stock or recommend a current alternative.
Shop online