The Elcometer 6910/3 Setaflash 'Series 3' Active-Cool Closed Cup Tester (part number K6910M013) is a portable flash point instrument built to carry out flash/no flash tests rapidly and to determine the flash point of liquids and semi-solids in the 10 degrees C to 135 degrees C range. It offers the same features as the Elcometer 6910/1 but is fitted with a cup suitable for testing corrosive samples. Flash point is the lowest temperature at which a sample gives off enough vapour to ignite, and a reliable, repeatable value underpins the correct classification, transport and storage of flammable products.

The sample cup is heated and then cooled by Peltier cells, giving accurate and stable sub-ambient test temperatures and rapid temperature normalisation between tests. Flash point is detected automatically by a thermally activated detector, which reduces the risk of operator error and limits exposure to fumes during a test. Two test modes are available, Flash/No Flash and Ramp, with a 2 degrees C/min ramp rate. A rechargeable gas tank with on/off switch and fine adjustment is integral to the Elcometer 6910/3 Setaflash 'Series 3' Active-Cool Closed Cup Tester.

Sample size is 2ml for flash points up to 100 degrees C and 4ml above that, with test duration of 1 minute below 100 degrees C, 2 minutes above, or a user-set 1 to 99 minutes. The cup uses a corrosion resistant steel insert. The instrument measures 195 x 295 x 140mm and weighs 3kg. It can be used in accordance with ASTM D1655, ASTM D3278, ASTM D3828, ASTM E502, BS 2000-523, CLP Regulations EC No 1272/2008, DEF STAN 91-91, EPA 1020 A and B, ISO 3679, ISO 3680 and UN Class 3 Non-viscous Flammable Liquids. Used in fuels, coatings and chemical testing, it is supplied by BAMR, South Africa's authorised distributor.

Elcometer

Elcometer 6910/3 Setaflash 'Series 3' Active-Cool Closed Cup Tester

SKU · K6910M013

The Setaflash 'Series 3' Active-Cool Tester offers the same features as the Elcometer 6910/1 Setaflash but is fitted with a cup suitable for testing corrosive samples. It has been designed to carry out flash/no flash tests rapidly and efficiently to determine the flash point of liquids and semi-solids in the 10°C to 130°C temperature range.

  • Flash/No Flash & Ramp Modes
  • Flash point test in less than 2 minutes
  • Small sample size, 2ml or 4ml
  • Automatic flash detection
  • Electronic Peltier cooling
  • Audible and on-screen prompts
  • Portable
  • Corrosion resistant cup insert
Indicative price
POA
Specialist-built quote, by close of business
Or ask a quick question on WhatsApp
Used by inspection teams in
RefiningMarineMiningBridge / civil
Specifications

Specifications

Part NumberDescriptionCertificate
K6910M013Elcometer 6910/3 Setaflash 'Series 3' Active-Cool Closed Cupο
Temperature Range10°C to 135°C
Test ModeRapid Equilibrium and Ramp
Sample Size2ml for flash points up to 100°C
Test Duration1 minute below 100°C, 2 minutes above 100°C, or user determined 1 to 99 minutes
Ramp Rate2°C/min ramp
Cup MaterialCorrosion resistant steel insert
Dimensions195 x 295 x 140mm
Weight3kg
Sample Size
2ml for flash points up to 100°C; 4ml for flash points above 100°C
Standards

Standards

ASTM
ASTM D1655
ASTM
ASTM D3278
ASTM
ASTM D3828
ASTM
ASTM E502
BSI
BS 2000-523
European Commission
CLP Regulations EC No 1272/2008
DEF STAN
DEF STAN 91-91
EPA
EPA 1020 A & B
ISO
ISO 3679
ISO
ISO 3680
UN
UN Class 3 Non-viscous Flammable Liquids
Accessories

Accessories

KT006910N001Cooling Module Option for 5°C Ambient Temperature
KT006910N009Certified Flash Point Material 50ml
Downloads
Answers

Frequently asked questions

When should I use the Elcometer 6910/3 instead of a standard Setaflash?

The 6910/3 has a corrosion-resistant steel cup, making it suitable for testing corrosive samples that would damage a standard tester.

What sample volumes are required for the Setaflash Series 3?

Sample volume depends on the expected flash point. Use 2ml for flash points up to 100°C, and 4ml for flash points above 100°C.

How long does a flash point test take?

Standard tests run for 1 minute below 100°C or 2 minutes above 100°C. You can also set custom durations between 1 and 99 minutes.

What test modes does the Series 3 support?

Both Rapid Equilibrium and Ramp test modes are available, allowing you to select the approach that suits your specific testing requirements.

Can I configure test parameters to my specifications?

The ramp rate is fixed at 2°C/min. Test duration is flexible, ranging from 1 to 99 minutes depending on your needs.

Request a quote

Quote on the Elcometer 6910/3 Setaflash 'Series 3' Active-Cool Closed Cup Tester by close of business.

Tell us about your application and we will send a quote with lead time and accessories.

Not sure this is the right model for your job? for a quick recommendation.

Request a quote

Request a quote

Tell us about your application and we will send a quote with lead time and accessories.

This form is protected against automated submissions.

Request a quote