Dakota ZX Thickness Gauge Comparison Table
Compare the Dakota ZX corrosion thickness gauge range at a glance. The headline specifications below cover measurement range, resolution and the transducer used across the ZX1, ZX2, ZX3, ZX5, ZX5-DL, ZX6 and ZX6-DL models to help you select the right gauge. The range runs from the entry level ZX1 to the data-logging ZX6-DL, with the ZX6 and ZX6-DL adding an Echo Echo measurement range for coated surfaces.
Dakota ZX1
- Part Number
- Z-300-0003
- Measurement Range
- PE: 0.63 – 914.4mm
- Measurement Resolution
- 0.01mm
- Velocity Calibration Range
- 305 – 18,542m/s
- Transducer Probe Type
- Dual element
- Transducer Frequency Range
- 1 – 10MHz
- Display
- 12.7mm 4.5 digit LCD
Dakota ZX2
- Part Number
- Z-301-0003
- Measurement Range
- PE: 0.63 – 914.4mm
- Measurement Resolution
- 0.01mm
- Velocity Calibration Range
- 305 – 18,542m/s
- Transducer Probe Type
- Dual element
- Transducer Frequency Range
- 1 – 10MHz
- Display
- 12.7mm 4.5 digit LCD
Dakota ZX3
- Part Number
- Z-302-0003
- Measurement Range
- PE: 0.63 – 914.4mm
- Measurement Resolution
- 0.01mm
- Velocity Calibration Range
- 305 – 18,542m/s
- Transducer Probe Type
- Dual element
- Transducer Frequency Range
- 1 – 10MHz
- Display
- 12.7mm 4.5 digit LCD
Dakota ZX5
- Part Number
- Z-303-0003
- Measurement Range
- PE: 0.63 – 914.4mm
- Measurement Resolution
- 0.01mm
- Velocity Calibration Range
- 305 – 18,542m/s
- Transducer Probe Type
- Dual element
- Transducer Frequency Range
- 1 – 10MHz
- Display
- 12.7mm 4.5 digit LCD
Dakota ZX5-DL
- Part Number
- Z-304-0003
- Measurement Range
- PE: 0.63 – 914.4mm
- Measurement Resolution
- 0.01mm
- Velocity Calibration Range
- 305 – 18,542m/s
- Transducer Probe Type
- Dual element
- Transducer Frequency Range
- 1 – 10MHz
- Display
- 12.7mm 4.5 digit LCD
Dakota ZX6
- Part Number
- Z-305-0003
- Measurement Range
- PE: 0.63 – 914.4mm EE: 2.54 – 152.4mm
- Measurement Resolution
- 0.01mm
- Velocity Calibration Range
- 305 – 18,542m/s
- Transducer Probe Type
- Dual element
- Transducer Frequency Range
- 1 – 10MHz
- Display
- 12.7mm 4.5 digit LCD
Dakota ZX6-DL
- Part Number
- Z-306-0003
- Measurement Range
- PE: 0.63 – 914.4mm EE: 2.54 – 152.4mm
- Measurement Resolution
- 0.01mm
- Velocity Calibration Range
- 305 – 18,542m/s
- Transducer Probe Type
- Dual element
- Transducer Frequency Range
- 1 – 10MHz
- Display
- 12.7mm 4.5 digit LCD
Specifications
Dakota ZX1
- Part Number
- Z-300-0003
- Measurement Range
- PE: 0.63 – 914.4mm
- Measurement Resolution
- 0.01mm
- Velocity Calibration Range
- 305 – 18,542m/s
- Transducer Probe Type
- Dual element
- Transducer Frequency Range
- 1 – 10MHz
- Display
- 12.7mm 4.5 digit LCD
Dakota ZX2
- Part Number
- Z-301-0003
- Measurement Range
- PE: 0.63 – 914.4mm
- Measurement Resolution
- 0.01mm
- Velocity Calibration Range
- 305 – 18,542m/s
- Transducer Probe Type
- Dual element
- Transducer Frequency Range
- 1 – 10MHz
- Display
- 12.7mm 4.5 digit LCD
Dakota ZX3
- Part Number
- Z-302-0003
- Measurement Range
- PE: 0.63 – 914.4mm
- Measurement Resolution
- 0.01mm
- Velocity Calibration Range
- 305 – 18,542m/s
- Transducer Probe Type
- Dual element
- Transducer Frequency Range
- 1 – 10MHz
- Display
- 12.7mm 4.5 digit LCD
Dakota ZX5
- Part Number
- Z-303-0003
- Measurement Range
- PE: 0.63 – 914.4mm
- Measurement Resolution
- 0.01mm
- Velocity Calibration Range
- 305 – 18,542m/s
- Transducer Probe Type
- Dual element
- Transducer Frequency Range
- 1 – 10MHz
- Display
- 12.7mm 4.5 digit LCD
Dakota ZX5-DL
- Part Number
- Z-304-0003
- Measurement Range
- PE: 0.63 – 914.4mm
- Measurement Resolution
- 0.01mm
- Velocity Calibration Range
- 305 – 18,542m/s
- Transducer Probe Type
- Dual element
- Transducer Frequency Range
- 1 – 10MHz
- Display
- 12.7mm 4.5 digit LCD
Dakota ZX6
- Part Number
- Z-305-0003
- Measurement Range
- PE: 0.63 – 914.4mm EE: 2.54 – 152.4mm
- Measurement Resolution
- 0.01mm
- Velocity Calibration Range
- 305 – 18,542m/s
- Transducer Probe Type
- Dual element
- Transducer Frequency Range
- 1 – 10MHz
- Display
- 12.7mm 4.5 digit LCD
Dakota ZX6-DL
- Part Number
- Z-306-0003
- Measurement Range
- PE: 0.63 – 914.4mm EE: 2.54 – 152.4mm
- Measurement Resolution
- 0.01mm
- Velocity Calibration Range
- 305 – 18,542m/s
- Transducer Probe Type
- Dual element
- Transducer Frequency Range
- 1 – 10MHz
- Display
- 12.7mm 4.5 digit LCD
Frequently asked questions
Which Dakota ZX models include data logging?
The ZX5-DL and ZX6-DL models include data-logging functionality. Choose the ZX5-DL for standard PE-range logging, or the ZX6-DL if you also need Echo Echo measurement for coated surfaces.
What is the difference between PE and EE measurement ranges?
The PE range (0.63 to 914.4mm) covers standard thickness measurement. The EE (Echo Echo) range (2.54 to 152.4mm) is designed for coated surfaces. Only the ZX6 and ZX6-DL models offer both measurement capabilities.
Do all Dakota ZX models provide the same measurement resolution?
Yes. All models from the ZX1 through ZX6-DL deliver 0.01mm resolution, providing consistent precision across the entire product range.
Can I measure coated surfaces with the ZX1 or ZX5?
No. The ZX1 and ZX5 measure only in the PE range and lack Echo Echo capability. For coated surface measurement, you need a ZX6 or ZX6-DL.
Quote on the Dakota ZX Thickness Gauge Comparison Table by close of business.
Tell us about your application and we will send a quote with lead time and accessories.
Not sure this is the right model for your job? for a quick recommendation.
Request a quote
Request a quote
Tell us about your application and we will send a quote with lead time and accessories.
Shop online